All Messages

Q: Which UART number is dedicated foк S-BUS?

Asked by srgm_artworks on 2018-02-02 04:55:28

justindp2006 UART3 is for Serial RX. Make sure you set SBUS inversion to OFF. Depending on fw version it's command serialrx_inverted = OFF or sbus_inversion = off

2018-04-05 08:46:42 Helpful (0)
Submit
Answers (2)

Q: How do I get SBUS on this?

Asked by Justin420 on 2018-02-11 03:41:14

justindp2006 Make sure you set SBUS inversion to OFF. Depending on fw version it's command serialrx_inverted = OFF or sbus_inversion = off

2018-04-05 08:45:47 Helpful (0)
Submit
Answers (3)