220V 0.75KW/1.5KW/2.2KW Single Phase Motor Variable Frequency Drive Inverter COD

{{$productInfo.reviewAmount.average}} out of 5

5 Star 4 (80.0%)
4 Star 0 (0.0%)
3 Star 1 (20.0%)
2 Star 0 (0.0%)
1 Star 0 (0.0%)
5 Reviews
ID: 1461548
Sold: 0 SKUB83714 Stocks: 0
US$00.00
Price alert
Ship From:
CN
Power: Please select a Power
No shipping method is available for this product to your location.
Shipping: US$00.00
to Australia via
Shipping time: Arrival time = dispatch + shipping time
QTY:
This qualifies as a wholesale order,place an inquiry to receive our best price.Enquire Now!
Recommendation
    You May Also Like
    • Product details
    • Specification
    • Reviews (0)
    • Customer Q&As
    • Shipping & Payment

    Compatibility

    To confirm that this part fits your vehicle, please enter your vehicle's details below.
    • Year:
      Select
      • Make:
        Select
        • Model:
          Select
          • Submodel:
            Select
            • Trim:
              Select
              • Engine:
                Select
                • Clear All
                This part is compatible with 0 vehicle(s). Show all compatible vehicles
                This part is compatible with 1 vehicle(s) matching
                This part is not compatible with
                Recent searches
                  • Year
                  • Make
                  • Model
                  • Submodel
                  • Trim
                  • Engine
                    Specification:
                    Name:Variable Frequency Inverter
                    Input: 1PH 176-264V 50/60Hz
                    Output : 3PH 0-220V
                    Frequency Range: 0.01-400Hz
                    Motor power :0.75kw/1.5kw/2.2kw

                    Feature:
                    ★Inverter built-in temperature detection
                    ★Inverter comes with multi-function relay transmission, PID function, constant pressure water supply function.
                    ★The external controller can input 0~5v/0~10v analog voltage input and 0~20ma current signal input to realize stepless speed control.
                    ★The inverter has a quick start and stop response. The low speed torque is large. Immediately stop the short circuit to protect the host (short circuit protection)
                    ★The internal protection function has undervoltage, overvoltage, overcurrent, overheating, etc. The internal internal cooling function has lower requirements for the external environment.
                     
                    Danger:
                    1. Before wiring, make sure the input power is cut off.The risk of elecric shock and fire.
                    2. The need for wiring to the ectrial engineering professionals.The risk of eletric shock and fire.
                    3. The ground terminal must be grounded.The risk of eletric shock and fire.
                    4. After the emergency stop terminal is connected, be sure to check theoperation is valid.
                    Risk of injury. (Wiring is the responsibility borne by the user)
                    5. Do not touch the output terminal, an output terminal of the inverter must notbe connected with the housing, to avoid short circuit between the output terminals.
                    Risk of eletric shock and cause a short circuit.
                     
                    Notice:
                    1. Make sure the main AC power supply and the rated voltage of the inverter are the same.Risk of injury and fire.
                    2. Do not perform voltage withstand tests on the drive.It can cause damage to the semiconductor components and the like.
                    3. Press the wiring diagram to connect the braking resistor or braking unit.There are a fire hazard.
                    4. Tighten the terminal with the specified torque screwdriver.There are a fire hazard.
                    5. Do not conneet the power cable to the output U, v, w terminals.
                    Voltage applied to the output terminals may cause internal inverter damage.6. Do not phase-shifting capacitor output circuit.It can cause internal inverter damage.
                    7. Do not connect an electromagnetic switch, magnetic contactor to the outputcircuit. Inverter running with load, the electromagnetic switch and electromagneticcontactor operation inrush currents can cause drive over-current protection circuitoperation.

                    Package Included:
                    1 X 
                    Variable Frequency Inverter
                     












                    Customers who view this item also bought

                    Customer Reviews

                    Customer Q&As

                    Shipping Methods

                    The total estimated time it takes to receive your order is shown below:
                    • You place your order
                    • (Processing time)
                    • We ship your order
                    • (Shipping time)
                    • Delivery!
                    Total Estimated Delivery Time
                    The total delivery time is calculated from the time your order is placed until the time it is delivered to you. Total delivery time is broken down into processing time and shipping time.
                    Processing time: The time it takes to prepare your item(s) to ship from our warehouse. This includes preparing your items, performing quality checks, and packing for shipment.
                    Shipping time: The time for your item(s) to travel from our warehouse to your destination.
                    Recommended shipping methods for your country/region are shown below:
                    Ship to: Ship From
                    CN Warehouse
                    • CN Warehouse
                    • HK Warehouse
                    • USA Warehouse
                    • FR Warehouse
                    • AU Warehouse
                    • UK Warehouse
                    • GWTR Warehouse
                    • RU Warehouse
                    • ES Warehouse
                    • CZ Warehouse
                    • AE Warehouse
                    • BR Warehouse
                    • JP Warehouse
                    • PL Warehouse
                    This warehouse cannot ship to your location.
                    Shipping method(s) Shipping time Tracking information
                    Note:
                    (1) The shipping time mentioned above refers to the estimated time of business days that the shipment will take after an order has been shipped.
                    (2) Business days do not include Saturday/Sunday and any public holidays.
                    (3) These estimates are based on normal circumstances and are not a guarantee of delivery times.
                    (4) We are not responsible for the failures or delays in delivery resulting from any force majeure event, such as natural disaster, bad weather, war, customs issues, and any other event beyond our direct control.
                    (5) Expedited shipping can not be used for PO Box addresses

                    Payment methods

                    We support the following payment methods.Click for more information if you are confused about how to pay.
                    *We currently offer COD payments for Saudi Arabia, United Arab Emirates, Kuwait, Oman, Bahrain, Qatar, Thailand, Singapore, Malaysia, Philippines, Indonesia, Viet Nam, India. We will send a confirmation code to your mobile phone to verify that your contact details are correct. Please ensure you follow all the instructions contained in the message.
                    *Paying with Installment (credit card) or Boleto Bancário is only available for orders with shipping addresses in Brazil.

                    Wholesale Inquiry

                    • *
                    • *
                    • *
                    • 0/300
                    • *
                    • Australia
                      • Australia
                      *
                    • *
                    • Submit
                    Customers Who View This Item Also View